Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 55
Filter
1.
Braz. J. Pharm. Sci. (Online) ; 59: e21328, 2023. tab, graf
Article in English | LILACS | ID: biblio-1439548

ABSTRACT

Abstract The present study entails the systematic development and validation of a stability-indicating RP-HPLC method for the analysis of sitagliptin and ertugliflozin in a fixed-dose combination. Analytical quality by design (AQbD) concepts were used to define critical method variables, employing Pareto risk assessment and a Placket-Burman screening design, preceded by a Box-Behnken design with response surface analysis to optimise critical method parameters such as % acetonitrile (X1), buffer pH (X2) and column oven temperature (X3). Multiple response optimisation (Derringer's desirability) of variables was accomplished by studying critical analytical attributes, such as resolution, retention time and theoretical plates. The title analytes were separated effectively on a PRONTOSIL C18 column at 37 °C using a mobile phase of acetonitrile:acetate buffer, pH 4.4 (36:64 percent v/v), pumped at a flow rate of 1 mL/min, and UV detection at 225 nm. Linearity was observed over a concentration range of 25-150 µg/mL and 3.75-22.5 µg/mL at retention times of 2.82 and 3.92 min for sitagliptin and ertugliflozin, respectively. The method obeyed all validation parameters of the ICH Q2(R1) guidelines. The proposed robust method allows the study of the selected drugs in pharmaceutical dosage forms as well as in drug stability studies under various stress conditions.


Subject(s)
Drawing , Sitagliptin Phosphate/analysis , Pharmaceutical Preparations/administration & dosage , Chromatography, High Pressure Liquid/methods , Total Quality Management/classification , Hydrogen-Ion Concentration/drug effects
2.
Braz. J. Pharm. Sci. (Online) ; 58: e20570, 2022. tab, graf
Article in English | LILACS | ID: biblio-1403683

ABSTRACT

Abstract A stability indicating UPLC method has been developed and validated for the simultaneous determination of fosnetupitant and palonosetron in bulk and in injection dosage form. This combination is used for the prevention of acute and delayed nausea and vomiting associated with initial and repeated courses of highly emetogenic chemotherapy for cancer. The chromatographic analysis was performed on an HSS, RP C18 column (2.1 x 100 mm, 1.8 µm) with an isocratic mobile phase composed of 0.25 M potassium dihydrogen orthophosphate buffer (pH 6.5), pH adjusted with dilute sodium hydroxide:acetonitrile (55:45 v/v), at a flow rate of 0.5 mL/min, and the eluents were monitored at an isosbestic point of 286 nm. The developed method was validated according to the ICH guidelines pertaining to specificity, precision, accuracy, linearity and robustness, and the stability indicating nature of the method was established by forced degradation studies. The retention times of fosnetupitant and palonosetron were observed at 1.390 and 2.404 min, respectively. The developed method proved to be accurate and precise. Linearity was established between 4.70 and 14.10 µg/mL for fosnetupitant and between 0.05 and 0.15 µg/mL for palonosetron. The LOD and LOQ were 0.115 and 0.385 µg/mL, respectively, for fosnetupitant, and 0.005 and 0.016 µg/mL, respectively, for palonosetron. Therefore, the proposed UPLC method was reliable, reproducible, precise and sensitive for the quantification of fosnetupitant and palonosetron.


Subject(s)
Validation Study , Palonosetron/agonists , Injections/adverse effects , Methods , Diagnosis , Dosage Forms , Hydrogen-Ion Concentration , Neoplasms/prevention & control
3.
Rev. colomb. ciencias quim. farm ; 50(1): 61-85, Jan.-Apr. 2021. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1347314

ABSTRACT

SUMMARY Aim: A new stability-indicating liquid chromatography method was developed and validated for the quantitative determination of luliconazole. Materials and methods: Preliminary forced degradation study demonstrated an additional peak of the degradation product at the same retention time to the drug, due to this, the method was developed optimizing the chromatographic conditions to provide sufficient peak resolution (R ≥ 2). The experimental design was evaluated to assess the robustness and the best chromatographic conditions to be used for the validation. Methodology: Luliconazole solutions were exposed to various stress conditions to evaluate the method indication stability, in which the degradation product (DP-1) formed was isolated, identified, and evaluated in silico to predict degradation pathway and toxicity. The procedure was validated by robustness, selectivity, linearity, precision, and accuracy. Liquid chromatography was performed in a Phenomenex® RP-18 column with a mixture of acetonitrile and 0.3% (v/v) triethylamine solution as a mobile phase in isocratic elution. Results and conclusions: The method demonstrated robustness, good recovery, precision, linear response over a range from 5.0 to 40.0 μg.mL-1- and to be stability indicating. The alkaline stress condition resulted in the formation of DP-1. HRMS studies identified this product as an hydroxyacetamide derivative, and in silico studies did not show toxic potential.


RESUMEN Objetivo: Un nuevo método indicativo de estabilidad por cromatografía líquida fue desarrollado y validado para la determinación cuantitativa de luliconazol. Materiales y métodos: Estudios preliminares de degradación forzada demostraron un pico adicional en el mismo tiempo de retención del fármaco. El método desarrollado para optimizar las condiciones cromatográicas proporcionó una adecuada resolución (R ≥ 2). El diseño experimental fue evaluado para verificar su robustez y la mejor condición cromatográica para validación. Metodología: Las soluciones de luliconazol fueron expuestas a diferentes condiciones de estrés para evaluar la indicación de estabilidad del método, el aislamiento del producto de degradación formado (DP-1), su identificación y análisis in silico para predecir su ruta de degradación y toxicidad. El procedimiento se validó por robustez, selectividad, linealidad, precisión y exactitud. Las condiciones cromatográficas incluyeron una columna Phenomenex® RP-18, como fase móvil una mezcla de acetonitrilo y solución 0,3% (v/v) de trietilamina en elución isocrática. Resultados y conclusiones: El método mostró ser robusto, con buena recuperación, precisión, respuesta lineal en el rango de 5,0 a 40,0 μg.mL-1 e indicativo de la estabilidad. La condición de estrés alcalina resultó en la formación de DP-1. Estudios por HRMS identificaron este producto como un derivado hidroxiacetamida y los estudios in silico no mostraron potencial de toxicidad.


RESUMO Objetivo: Um novo método indicativo de estabilidade por cromatograia líquida foi desenvolvido e validado para a determinação quantitativa de luliconazol. Materiais e métodos: Estudos preliminares de degradação forçada demonstraram um pico adicional no mesmo tempo de retenção do medicamento. O método desenvolvido para otimizar as condições cromatográficas proporcionou resolução adequada (R ≥ 2). O delineamento experimental foi avaliado para verificar sua robustez e a melhor condição cromatográica para validação. Metodologia: Soluções de luliconazol foram expostas a diferentes condições de estresse para avaliar a indicação da estabilidade do método, o isolamento do produto de degradação formado (DP-1), sua identificação e análise in silico para predizer sua rota de degradação e toxicidade. O procedimento foi validado quanto à robustez, seletividade, linearidade, precisão e exatidão. As condições cromatográficas incluíram uma coluna Phenomenex® RP-18, como fase móvel uma mistura de acetonitrila e solução de trietilamina 0,3% (v/v) em eluição isocrática. Resultados e conclusões: O método mostrou-se robusto, com boa recuperação, precisão, resposta linear na faixa de 5,0 a 40,0 μg.mL-1 e indicativo de estabilidade. A condição de estresse alcalino resultou na formação de DP-1. Os estudos da HRMS identificaram este produto como um derivado da hidroxiacetamida e os estudos in silico não mostraram nenhum potencial de toxicidade.

4.
Article | IMSEAR | ID: sea-206299

ABSTRACT

The discovery of new direct-acting antiviral drugs gave rise to a leap forward in the treatment of hepatitis C viral infections. For the first time since 1998, the Food and Drug Administration (FDA) approved interferon-free oral treatment paradigms. Among the new treatment regimens, the combinations of Sofosbuvir and Velpatasvir became ideal treatment regimens for being potent, highly tolerated and used once daily. Hence an accurate, precise, selective and sensitive stability indicating method for simultaneous estimation of Sofosbuvir and Velpatasvir by High-Performance Thin Layer Chromatography has been developed and validated. Chromatographic separation was achieved on TLC plates coated with silica gel 60 F254 as stationary phase. Ethyl acetate: iso-propyl alcohol (9:1 v/v) was used as mobile phase.Densitometric scanning was carried out at 260 and 302 nm for Sofosbuvir and Velpatasvir, respectively. The method was successfully validated as per the ICH Guideline. The linear concentration range was100- 2000 ng/band (r2= 0.991) and 100-500 ng/band (r2 = 0.991) for SOF (Sofosbuvir) and VEL (Velpatasvir) respectively. The LOD were 25.16 ng/band and 9.96 ng/band for SOF and VEL, LOQ were 76.25 ng/band and 30.19 ng/band for SOF and VEL.The method could be applied to the quality control and routine analysis of Sofosbuvir and Velpatasvir in their pure forms and pharmaceutical formulations.

5.
Article | IMSEAR | ID: sea-210694

ABSTRACT

Sacubitril/Valsartan (SAC/VAL) is a combination drug used for the treatment of heart failure. In the present work,novel and rapid, sensitive, specific, and robust ultra high-performance liquid chromatography method was developedand validated for the simultaneous estimation of SAC/VAL in presence of their seven related impurities anddegradation products. The chromatographic separation was achieved on Accucore XL C8, (100 × 4.6) mm; 3 μmreverse phase column maintained at 30°C. The peaks were eluted using tetrahydrofuran (THF) and 0.1% perchloricacid in water (8:92, %v/v) as a mobile phase A and THF:water:acetonitrile (5:15:80, %v/v/v) as mobile phase B in agradient mode. The flow rate was set at 0.6 ml/minute and the analytes were monitored in the range of 200–400 nmusing a Photo Diode Array (PDA) detector for 21 minutes run time. The method was validated as per ICH Q2 (R1)guideline and all the validation parameters were found within the acceptance criteria. The forced degradation studyfor SAC/VAL showed that the drugs were prone to acidic, alkaline, and neutral hydrolytic as well as oxidative stressconditions. All the degradation products were separated from each other, SAC/VAL and their impurities showing thestability indicating power of the method. The newly developed method can be used for estimation of assay and relatedsubstances from bulk or their finished products with good efficiency.

6.
Braz. J. Pharm. Sci. (Online) ; 56: e18817, 2020. tab, graf
Article in English | LILACS | ID: biblio-1132040

ABSTRACT

A simple, accurate, precise and robust stability indicating RP-HPLC assay method has been developed for the estimation of trimethobenzamide in stress sample. An isocratic separation of trimethobenzamide was achieved on Kromasil 100 C-18 column (250 X 4.6mm, 5µ) with a flow rate of 1.0 ml/min and by using a photodiode array detector to detect the analyte at 213nm. The optimized mobile phase consisted of methanol: ammonium formate (44:56, v/v). The drug was subjected to different forced degradation conditions according to ICH guidelines including acid, base, neutral hydrolysis, oxidation, photolysis and thermal degradation. Degradation products were found only in basic and oxidative degradation conditions. All the degradation products got eluted in an overall analytical run time of 12min. The developed analytical method has been validated according to the ICH guidelines. Response of trimethobenzamide was linear over the concentration range of 0.5-50µg/mL (r2 = 0.999). Accuracy was found to be in between 94.03% to 100.39%. Degradation products resulting from the stress studies did not interfere with the detection of the analyte.


Subject(s)
Chromatography, High Pressure Liquid/methods , /analysis , Validation Study , Methods , Pharmaceutical Preparations/administration & dosage , Hydrolysis
7.
Braz. J. Pharm. Sci. (Online) ; 56: e17758, 2020. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1089171

ABSTRACT

We developed and validated a stability-indicating assay method for the simultaneous determination of enrofloxacin and piroxicam in combination and in the presence of degradation products. Reverse-phase high-performance liquid chromatography analyses were carried out on a Vertisep C18 column and acetonitrile-water (48:52 v/v, pH 3.0) mobile phase with a 1.00 mL min−1 flow rate. The efficient chromatographic separation of these drugs and their forced degradation products was achieved in less than 5min with a peak purity match factor higher than 950. The method used showed linearity in the concentration ranges of 0.25 to 16.0 µg mL−1 for enrofloxacin (r = 0.9997) and 0.125 to 8.0 µg mL−1 for piroxicam (r = 0.9999) as well as precision (relative standard deviation lower than 2%), accuracy (mean recovery 100 ± 2%), and robustness, according to ICH (International Conference on Harmonization) and AOAC (Association of Official Analytical Chemists) guidelines. This method can simultaneously determine the combination of these drugs in a veterinary formulation and separate the drug peaks from their forced degradation products. Additionally, its optimized chromatographic conditions can contribute to the quality control of this formulation in pharmaceutical manufacturing plants and minimize waste from the organic solvent.

8.
Braz. J. Pharm. Sci. (Online) ; 56: e18162, 2020. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1089199

ABSTRACT

Resumo Amiodarone hydrochloride is one of the most important drugs used to treat arrhythmias. The USP monograph for amiodarone hydrochloride describes an HPLC method for the quantification of seven impurities, however, this method shows problems that result in unresolved peaks. Moreover, there is no monograph for tablets in this compendium. Thus, a stability indicating HPLC method was developed for the determination of amiodarone, its known impurities and degradation products in tablets. A detailed forced degradation study was performed submitting amiodarone API, tablets and placebo to different stress conditions: acid and alkaline hydrolysis, oxidation, metal ions, heat, humidity, and light. Amiodarone hydrochloride API was susceptible to degradation in all stress conditions. The tablets also showed degradation in all environments, except in acidic condition. The analytes separation and quantification were achieved on an Agilent Zorbax Eclipse XDB-C18 column (100 x 3.0 mm, 3.5 µm). The mobile phase was composed of 50 mM acetate buffer pH 5.5 (A) and a mixture of methanol-acetonitrile (3:4, v/v) (B) in gradient elution. The method was validated in the range of 350-650 µg/mL for assay and 10-24 µg/mL for impurities determination. Therefore, this method can be used both for stability studies and routine quality control analyses.

9.
Braz. J. Pharm. Sci. (Online) ; 56: e18420, 2020. tab, graf
Article in English | LILACS | ID: biblio-1249160

ABSTRACT

A new stability-indicating liquid chromatographic method was developed and validated for the estimation of glycopyrrolate in pharmaceutical formulations. A contemporary approach to analytical life-cycle management was followed to develop a robust and reliable chromatographic method. Scouted method variables such as % methanol, the strength of tetra butyl ammonium hydrogen sulfate and mobile phase flow rate were optimized using the design of experiment approach and their effect on critical quality attributes was studied. The critical quality attributes viz. retention time, theoretical plate count and symmetry factor were highly influenced by the three critical method variables. Optimum chromatography was attained on a C-18 column with a mobile phase methanol: 10 mM tetra butyl ammonium hydrogen sulfate (80:20, v/v) flowing at 1.0 mL.min-1. Chromatographic method specificity was ensured by degrading the drug forcefully. Validation studies postulated method acceptability and suitability for estimating glycopyrrolate in both bulk as well as injection formulation. Results for parameters viz. linearity (5-250 µg.mL-1), accuracy (>99%) and precision (<2%) advocated method reliability. Overall the method was reliable and of optimum quality and, possess the potential of application in routine and bio-analytical purposes


Subject(s)
Chromatography/instrumentation , Chromatography, Liquid/methods , Validation Study , Glycopyrrolate/agonists , Pharmaceutical Preparations , Sensitivity and Specificity , Characidae/classification , Injections/adverse effects , Methods
10.
Chinese Journal of Experimental Traditional Medical Formulae ; (24): 129-134, 2020.
Article in Chinese | WPRIM | ID: wpr-872802

ABSTRACT

Objective::To study the degradation of salvianolate lyophilized injection (SLI) and establish a stability-indicating analysis method. Method::UPLC-Q-TOF-MS/MS was used to conduct a qualitative study on the main components of SLI, and a stability-indicating analysis method was established for simultaneous determination of the original components of SLI and its degradation products. The stability of SLI were systematically assessed under physicochemical conditions of high temperature, oxidation, metal ions. Result::Totally 13 main active ingredients in SLI were identified, and a semi-quantitative analysis was performed. Under the conditions of high temperature, oxidation, light, trivalent ion and divalent ion, 6, 4, 3, 4 and 1 new degradation products were added respectively. The established stability-indicating analysis method can simultaneously determine the degradation products of the main components and their active components in SLI, with a good separation effect. Conclusion::According to the degradation mechanism of the main ingredients in SLI, macromolecular polyphenol acid compounds are degraded into small molecular compounds, such as tanshinol and protocatechu aldehyde by a series of reactions, like benzofuran open-loop, hydrolysis of ester bond and removal of DSS. The stability-indicating analysis method can be used for the stability quality control of traditional Chinese medicine Salvianolate Lyophilized Injection (SLI).

11.
Int J Pharm Pharm Sci ; 2019 May; 11(5): 37-42
Article | IMSEAR | ID: sea-205895

ABSTRACT

Objective: To develop and validate simple, sensitive stability indicating HPTLC (High performance thin layer chromatography) method for apixaban. Methods: The chromatographic separation was performed on aluminium plates precoated with silica gel 60 F254 using toluene: ethyl acetate: methanol (3:6:1 v/v/v) as mobile phase followed by densitometric scanning at 279 nm. Results: The chromatographic condition shows sharp peak of apixaban at Rf value of 0.38±0.03. Stress testing was carried out according to international conference on harmonization (ICH)Q1A (R2) guidelines and the method was validated as per ICH Q2(R1) guidelines. The calibration curve was found to be linear in the concentration range of 100-500 ng/band for apixaban. The limit of detection and quantification was found to be 11.66ng/bandand35.33ng/band, respectively. Conclusion: A new simple, sensitive, stability indicating high performance thin layer chromatographic (HPTLC) method has been developed and validated for the determination of apixaban.

12.
Journal of Pharmaceutical Analysis ; (6): 83-90, 2019.
Article in Chinese | WPRIM | ID: wpr-744112

ABSTRACT

Standard parenteral nutrition solutions are mixtures comprising interacting components that may de-grade themselves over time. The objective of this study was to investigate the physicochemical and microbiological stability of a hospital preparation for parenteral nutrition in neonatology. The analyses were performed throughout the storage of the preparations at 2–8 °C (up to 4 months). The extent of stability was based on the determination of amino acids dosage, visual and physicochemical properties (glucose and electrolytes concentrations, pH and osmolality measurements, particle counting) and mi-crobiological analysis (sterility test). A thermal degradation of ascorbic acid was conducted to evaluate the antioxidant properties of the parenteral mixture. Physicochemical and microbiological controls were found to comply with the specifications. Amino acids showed a good stability throughout the 4months storage except for cysteine, which was progressively degraded to cystine, conferring a yellow coloration to parenteral solutions. Parenteral nutrition standards solutions remain stable for 4 months at 2–8 °C, ensuring safe administration in preterm infants.

13.
Journal of Pharmaceutical Analysis ; (6): 386-393, 2018.
Article in Chinese | WPRIM | ID: wpr-700397

ABSTRACT

A lock solution composed of gentamicin sulfate (5 mg/mL) and ethylenediaminetetraacetic acid disodium salt (EDTA-Na2, 30 mg/mL) could fully eradicate in vivo bacterial biofilms in totally implantable venous access ports (TIVAP). In this study, fabrication, conditioning and sterilization processes of antimicrobial lock solution (ALS) were detailed and completed by a stability study. Stability of ALS was conducted for 12 months in vial (25 °C ± 2 °C, 60% ± 5% relative humidity (RH), and at 40 °C ± 2 °C, RH 75% ± 5%) and for 24 h and 72 h in TIVAP (40 °C ± 2 °C, RH 75% ± 5%). A stability indicating HPLC assay with UV detection for simultaneous quantification of gentamicin sulfate and EDTA-Na2 was developed. ALS was assayed by ion-pairing high performance liquid chromatography (HPLC) needing gentamicin derivatization, EDTA-Na2 metallocomplexation of samples and gradient mobile phase. HPLC methods to separate four gentamicin components and EDTA-Na2 were validated. Efficiency of sterility procedure and conditioning of ALS was confirmed by bacterial endotoxins and sterility tests. Physicochemical stability of ALS was determined by visual inspection, osmolality, pH, and sub-visible particle counting. Results confirmed that the stability of ALS in vials was maintained for 12 months and 24 h and 72 h in TIVAP.

14.
Braz. J. Pharm. Sci. (Online) ; 54(3): e00223, 2018. tab, graf
Article in English | LILACS | ID: biblio-974412

ABSTRACT

Forced degradation studies of gliquidone were conducted under different stress conditions. Three degradates were observed upon using HPLC and TLC and elucidated by LC-MS and IR. HPLC method was performed on C18 column using methanol-water (85:15 v/v) pH 3.5 as a mobile phase with isocratic mode at 1 mL.min-1 and detection at 225 nm. HPLC analysis was applied in range of 0.5-20 µg.mL-1 (r =1) with limit of detection (LOD) 0.177 µg.mL-1. TLC method was based on the separation of gliquidone from degradation products on silica gel TLC F254 plates using chloroform-cyclohexane-glacial acetic acid (6:3:1v/v) as a developing system with relative retardation 1.15±0.01. Densitometric measurements were achieved in range of 2 -20 µg /band at 254 nm (r = 0.9999) with LOD of 0.26 µg /band. Least squares regression analysis was applied to provide mathematical estimates of the degree of linearity. The analysis revealed a linear calibration for HPLC where a binomial relationship for TLC. Stability testing and methods validation have been evaluated according to International Conference on Harmonization guidelines. Moreover, the proposed methods were applied for the analysis of tablets and the results obtained were statistically compared with those of pharmacopeial method revealing no significant difference about accuracy and precision.


Subject(s)
Chromatography, High Pressure Liquid/methods , Hypoglycemic Agents/metabolism , Densitometry/methods , Diabetes Mellitus, Type 2/drug therapy , Drug Stability
15.
Braz. J. Pharm. Sci. (Online) ; 54(2): e17491, 2018. tab, graf
Article in English | LILACS | ID: biblio-951933

ABSTRACT

ABSTRACT Multifunctional drug anisomycin was subjected to forced degradation in accordance with International Conference on Harmonisation (ICH) guidelines for the first time. The drug was exposed to the recommended stress conditions of hydrolysis (acidic, alkaline and neutral), oxidation, thermal stress and photolysis, in order to investigate its stability. Optimized LC-MS/MS method was validated as recommended by ICH Q2(R1) guideline with respect to the specificity, accuracy, precision, limits of detection and quantitation, linearity and robustness. Anisomycin exhibited high instability under alkaline and thermal (neutral hydrolysis) conditions. It showed moderate stability under acidic, neutral, oxidative, thermal (acidic hydrolysis) and photolytic conditions, with the lowest degradation level observed in the case of light and oxidation stress. Formation of the same degradation product, identified as deacetylanisomycin, was observed under all applied stress conditions.


Subject(s)
Evaluation Studies as Topic , Anisomycin/analysis , Mass Spectrometry/methods , Chromatography, Liquid/methods , Validation Study
16.
Journal of Pharmaceutical Analysis ; (6): 237-243, 2017.
Article in Chinese | WPRIM | ID: wpr-617993

ABSTRACT

A new institutional clinical trial assessed the improvement of sleep disorders in 40 children with autism treated by immediate-release melatonin formulation in different regimens (0.5 mg, 2 mg, and 6 mg daily) for one month. The objectives of present study were to (i) prepare low-dose melatonin hard capsules for pediatric use controlled by two complementary methods and (ii) carry out a stability study in order to determine a use-by-date. Validation of preparation process was claimed as ascertained by mass uniformity of hard capsules. Multicomponent analysis by attenuated total reflectance Fourier transformed infrared (ATR-FTIR) of melatonin/microcrystalline cellulose mixture allowed to identify and quantify relative content of active pharmaceutical ingredients and excipients. Absolute melatonin content analysis by high performance liquid chromatography in 0.5 mg and 6 mg melatonin capsules was 93.6% ± 4.1% and 98.7% ± 6.9% of theoretical value, respectively. Forced degradation study showed a good separation of melatonin and its degradation products. The capability of the method was 15, confirming a risk of false negative < 0.01%. Stability test and dissolution test were compliant over 18 months of storage with European Pharmacopoeia. Preparation of melatonin hard capsules was completed manually and melatonin in hard capsules was stable for 18 months, in spite of low doses of active ingredient. ATR-FTIR offers a real alternative to HPLC for quality control of high-dose melatonin hard capsules before the release of clinical batches.

17.
Journal of Pharmaceutical Analysis ; (6): 134-140, 2017.
Article in Chinese | WPRIM | ID: wpr-513419

ABSTRACT

A stability-indicating reverse phase–high performance liquid chromatography (RP–HPLC) method was developed and validated for the determination of atazanavir sulfate in tablet dosage forms using C18 column Phenomenix (250 mm×4.6 mm, 5μm) with a mobile phase consisting of 900 mL of HPLC grade methanol and 100 mL of water of HPLC grade. The pH was adjusted to 3.55 with acetic acid. The mobile phase was sonicated for 10 min and filtered through a 0.45μm membrane filter at a flow rate of 0.5 mL/min. The detection was carried out at 249 nm and retention time of atazanavir sulfate was found to be 8.323 min. Linearity was observed from 10 to 90μg/mL (coefficient of determination R2 was 0.999) with equation, y=23.427x+37.732. Atazanavir sulfate was subjected to stress conditions including acidic, alkaline, oxidation, photolysis and thermal degradation, and the results showed that it was more sensitive towards acidic degradation. The method was validated as per ICH guidelines.

18.
Braz. J. Pharm. Sci. (Online) ; 53(3): e00041, 2017. tab, graf
Article in English | LILACS | ID: biblio-889383

ABSTRACT

ABSTRACT A stability indicating HPLC method to determine diltiazem hydrochloride (DTZ) in tablets and compounded capsules was developed and validated according to Brazilian and the International Conference on Harmonization (ICH) guidelines. The separation was carried out on a Purospher Star® C18 (150 x 4.6 mm i.d., 5 µm particle size, Merck Millipore) analytical column. The mobile phase consisted of a 0.05% (v/v) trifluoroacetic acid aqueous solution and a 0.05% trifluoroacetic acid methanolic solution (44:56, v/v). The flow rate was 1.0 mL.min-1 with a run time of 14 minutes. The detection of DTZ and degradation products (DP) was performed at 240 nm, using a diode array detector. The method proved to be linear, precise, accurate, selective, and robust, and was adequate for stability studies and routine quality control analyses of DTZ in tablets and compounded capsules.


Subject(s)
Diltiazem/therapeutic use , Chromatography, High Pressure Liquid/methods , Validation Study , Tablets/pharmacology , Capsules/pharmacology
19.
Article in English | IMSEAR | ID: sea-180439

ABSTRACT

A novel stability-indicating Reverse Phase High Pressure Liquid Chromatography (RP-HPLC-PDA) method was developed and validated for quantitative determination of Camptothecin (CPT) in bulk, formulation and in dissolution samples using Inertsil-C18 (250mm x 4.6mm, 5μm) column with mobile phase combination of 15mM Ammonium acetate and acetonitrile (60:40) at a flow rate of 1mL/min. Eluents were monitored at a wavelength of 254 nm with an injection volume of 20µL. CPT was completely degraded in oxidative and base hydrolysis conditions and around 37% in acidic conditions and no degradation of CPT was observed with thermal, thermal/humidity and photo conditions. CPT showed linearity over a concentration range of 2-10μg/mL with a regression coefficient (R2) of 0.994 and correlation coefficient (R) of 0.999. The limit of detection (LOD) and limit of quantification (LOQ) values for CPT were 0.025μg/mL and 0.077μg/mL respectively. The developed method was validated as per ICH guidelines. The method was also successfully applied to dissolution testing of controlled release formulation.

20.
Braz. j. pharm. sci ; 52(3): 447-457, July-Sept. 2016. tab, graf
Article in English | LILACS | ID: biblio-828260

ABSTRACT

ABSTRACT Fusidic acid is an antibiotic steroid indicated for the treatment of infections caused by the genus Staphylococcus, including methicillin resistant Staphylococcus aureus strains, and other Gram-positive bacteria. In the present study, a stability-indicating reversed-phase liquid chromatography (RP-LC) method was developed and validated for the determination of fusidic acid in dermatological cream as an alternative to existing methods. Analyses were performed using a C18 column and guard column at room temperature, eluting with an isocratic mobile phase of acetonitrile and water (72:28, v/v), adjusted to pH 3.5 with acetic acid, pumped at a flow rate of 1.0 mL min-1, detection at 210 nm and 20 µL of injection volume. The forced degradation study was conducted under acidic, alkaline, neutral, photolytic, and oxidative stress conditions. The method was validated according to ICH and FDA guidelines; it was linear, precise, accurate, selective, and robust over concentrations of 5-95 µg mL-1, with detection and quantification limits of 0.43 and 1.31 μg mL-1, respectively. Therefore, we conclude that this method is suitable for quantifying fusidic acid in pharmaceutical dermatological creams and determining its stability, representing a more economical and practical alternative for routine analysis in quality control.


Subject(s)
Chromatography, High Pressure Liquid/methods , Fusidic Acid/pharmacokinetics , Dermatology/methods , Cosmetic Stability , Chromatography, Reverse-Phase
SELECTION OF CITATIONS
SEARCH DETAIL